Serial / Drivers Instrument Drivers (E-DAS Ambient 5.50 and above)

If you have E-DAS Ambient 5.50 and above, you can simplify the setup of digital data acquisition and collection of diagnostic parameters using the Digital Instrument Wizard. The files below can be copied into your DigitalInstrumentDrivers directory (usually located under C:\Program Files\E-DAS Ambient) and will appear automatically as a selection in the wizard.

Be advised that the drivers are designed using the default device ID codes ("4" for R&P TEOMs and FRMs), and may require modification if your device ID does not use the default code.

*** Update- July 2008 ****

Added Climatronics AIO Driver and Application Note
Added Magee Scientific Driver

*** Update- February 2008 ****

Update to 400E driver for latest API firmware

*** Update- September 2007 ****

Fixed error in Thermo 42C and 42i drivers for NO2 reading.

*** Update- July 2007 ****

Updated API drivers (200E, 400E) for latest API firmware revisions. Added Thermo (R&P) Partisol driver.

*** Update- May 2007 ****

Added driver for TECO 5020C Sulfate analyzer.

*** Update- March 2007 ****

I-series drivers (serial) now available. Application note on using Ethernet / Modbus interface also available. Revised drivers to reflect that Thermo analyzer CLINK and iSeries only returning PPB values.

*** Update- February 2007 ****

Update time storage issue in Tekran drivers. I-series drivers under testing (currently, changing parse width to 10 characters seems to work, but we are still testing). I-series Modbus drivers under testing as well.

*** Update- January 2007 ****

Fix made to TEOM driver for flow reading.

*** Update- October 2006 ****

Sunset Labs BOC Driver Added- see application notes for additional details. Credit to Paul Nichols, State of Maine for this driver!

Optec NGN-2A Driver Added.

*** Update- September 2006 ****

Looking for drivers for black carbon / organic carbon monitors or aethelometers? These devices tend to be a little particular with respect to the number of beams/wavelengths used, but they are available for Magee, Sunset Labs, and Optec monitors. Click here to get more information.

*** Update- March 16, 2006 ****

We have identified some issues with the Thermo 49C (ozone) analyzer and how it interfaces serially to the Model 8816 and Model 8832 data loggers.   As the response from the analyzer for the base ozone reading is just "o3" with no other discriminators, it isn't easy for the 8816/8832 to distinguish whether to get ready to receive the ozone reading, or if the analyzer is going to send "o3 bkgd" or "o3 coef" data.

We have posted alternate versions drivers (see right) that can resolve this protocol limitation.   However this solution also requires a "dongle" type device on the RS-232 port.   I have included a diagram with this email on how to build the dongle (pretty simple), or you may purchase them from Agilaire for $29 each.   The dongle drivers will not work without the dongle.

Note that this problem will not be an issue with Thermo's i-Series analyzers, which use a better transport layer (Ethernet) and standard protocol (Modbus) that can be enabled on Model 8832s- contact us for pricing for the Modbus interface if you have or will be getting i-Series analyzers and would like to take advantage of these features.

 

For more information, contact ESC Agilaire Support:

email: support@agilairecorp.com
phone: 865-688-7900s

Download The Latest Drivers
(*updated May 18- file for NOy analyzer was incorrect file)

Be advised that many drivers have not been QA's against all versions of analyzers out there, and that there are undocumented quirks in some of the protocols. All drivers should, for now, be tested in a lab setting before field use.

Note that use of the NOy driver requires changing the default ID from "42" to "40" to avoid confusion with other analyzers.

API Model 100 (SO2)
API Model 200 (NOX)
API Model 200E (NOX)

API Model 300 (CO)
API Model 400 (O3)
API Model 400E (O3)

R&P FDMS(default ID=4)
R&P TEOM (default ID=4)
R&P Partisol (default ID=4)

Non-Dongle Versions:
TECO 5020C Sulfate
TECO 42C (NOX)*
TECO 43C (SO2)
TECO 49C (O3)*
TECO NOy Trace
TECO 42i (NOX)*
TECO 43i (SO2)
TECO 49i (O3)*
TECO 48i (CO)

Dongle Versions:
D_TECO 42C (NOX)*
D_TECO 43C (SO2)
D_TECO 49C (O3)*
D_TECO NOy Trace

TECO 42i (NOX)*
TECO 43i (SO2)
TECO 49i (O3)*
TECO 48i (CO)

Thermo iSeries/Modbus Instructions

Tekran 2537A
Tekran 2537A (A/B channel data differentiated)

Optec NGN-2A

Magee Scientific

Sunset Labs BOC (see application notes!)
Allweather 8340 Ceilometer
Climatronics AIO Weather (see application note)

 


For copies of older manuals contact support@agilairecorp.com


 

Air quality monitoring and environmental software by Ambient Software will allow you to measure your air quality index and adjust accordingly to the EPA Standards and create a report by collecting local environmental data provided by Agilaire Corporation for Ambient Software, Air Quality Monitoring, Air Monitoring Equipment, Ambient Air, Environmental Monitoring, Air Quality Control, Air Quality Monitor, Air Monitoring, Air Quality Index, Air Quality Management, Environmental Software, Ambient Communication Computing Intelligence Mobile Networking Ubiquitous Wireless, Data Environmental Management, Environmental Management System Software, Air Quality Measurement, Air Quality Map, Air Quality, Air Data Computer, Air Quality Management District, Air Quality And Health, Air Quality Report, Air Quality Analyzer, Air Quality Equipment Services, Air Archive Data Toxics, Air Data Accessory, Air Pollution Quality, Environmental, Environmental Science, Indoor Air Quality, Environmental Pollution, Environmental Protection Agency, Environmental Chemistry, Environmental Testing, Us Epa, Ips Meteostar, Epa Standard, Air Quality Program, Collecting Local Environmental Data, Air Data Product, Department Of Environmental Management